Typical Type: Down-Flow ,Fully Wet Back,Three-Pass Shell Boiler
1.Oil(Gas)Fired Steam Boiler is of the type three-pass with wet   back and central back-flame in the seriesl steam output more than 1T/H,flame   tubes are symmetrical on furnance axis,uniform distribution is good to improve   the stress of the Tube plates,fully wet back structure combustion chanmber   inundates water completely so cooling conditions is good and back tube plates   will not be scoured by the high-temp smoke,so the boiler running conditions and   durability can be improved.
      2.The application of corrugated furnance not only   increase the heating area but also lessened the damnification to buring chamber   because of expansion on heating and contracting on cooling,Big volume furnance   leads to completely buring and can save fuel.
      3.Front flame box fit by   gemel,which can bring much convenience to open.After it is opened the furnance   and flame tubes can be approached to clean and maintain.What’s more,big volunm   furnance design can reduce the temperature of front flame box to avoid being   damaged.
      4. Big steam space reduces the speed of the steam seperating from   the surface of the water.The inner water separator set can insure high quality   steam output.
      5.Blow down automatically:The blow down valve is controled   according to the concentration of boiler ,it will be opened when concentration   reach to the blow down values,normally,it will be closed.(The acts above will   run automatically when the boiler is stopping) so it can save labour more and   lessen the waste of water and fuel,slower the form of fur-scale efficiently in   the boiler,and extend the life of boiler.
      6.Package construction and main   auxiliary pre-assembled considerably reduce installation costs.
      7.Boiler can   be operated completely by just using the fingers to press keys in the   intelligentize digital control system
      8.Perfect protection:over-pressure   switch on interlocking protection device,controllers giving alarms,burner   stopped,blow down automatically with safety valves oppenning.
      9.Convenient   maintenance: there is a access on top of the boiler for cleaning and maintenance   if it’s needed.
      10.All of the boilers are tested with rated load in order to   ensure the performance and reliability of burner,automatical controlling   apparatus and rated security units.
      (0.8Mpa and smaller series with function   of automatical blow down and fur-scale detecting)

The control system provides   functions such as automatic running ,manual running,timing-set running,failure   logging and password protection 
      1.Operated with function of timing-set,the   system can turn into on duty or off duty automatically. Control system can set   three groups timing period in 24 hours. The system will turn into on duty when   present time is in any stage of three groups,and touch screen will display the   same as automatic mode while the timing is in a on duty stage.It is a off duty   stage beyond a on duty atate.Each timing period includes a turn on time   (Hour,minute) and a turn off time (Hour,minute).The hour and minute of the three   group timing stages and current time can be set and reset. The user can set   varying temperature range at varying time.
      2.Failure logging: when a failure   occurs,the touch screen will give an alarm simultaneously and record the reason   and time of this failure. The controller can record the latest 5 failures   forever for further query.
      3.Passwort protection: you can set a password for   the controller to prevent others change the operation parameters unconsciously   while may bring an abnormal running.You can select to turn on password   protection (password protection is available) or turn off password protection   (password protection is not available).


PDF Download: Technical Data of Steam Boiler